RF12(1/2″)

Construction

Inner conductor 

Corrugated copper tube 

Φ4.83 mm 

Dielectric 

Foam PE 

Φ12.95 mm 

Outer conductor 

Corrugated copper 

Φ13.97 mm 

Sheath 

PE/LSOH 

Φ15.88 mm 

Electrical & Mechanical Characteristics

Impedance 

50±3 Ohm 

Nominal capacitance 

76 pF/m 

Velocity of propagation 

88%

Insulation resistance 

>5000 Mohm.Km 

Inner conductor resistance 

1.48 Ohm/Km 

Outer conductor resistance 

1.90 Ohm/Km 

Installation temperature range 

-40°C - +60 °C 

Operating temperature range 

-55°C - +85°C 

Test voltage 

4 KV 

Cable weight (approx.) 

220kg/km 

Operating Frequency Band 

1 – 8800 MHz 

Screening effectiveness 

>120dB 

Attenuation

Frequency  

Attenuation  

Attenuation  

Frequency  

Attenuation  

Attenuation  

(MHz)

(dB/100m)

(dB/100ft)

(MHz)

(dB/100m)

(dB/100ft)

10

0.67

0.2

1800

10.06

3.07

100

2.17

0.66

2000

10.67

3.25

150

2.67

0.81

2100

10.96

3.34

200

3.1

0.95

2200

11.25

3.43

300

3.84

1.17

2300

11.54

3.52

450

4.75

1.45

2500

12.09

3.69

500

5.02

1.53

2700

12.63

3.85

700

6.01

1.83

3000

13.41

4.09

800

6.46

1.97

4000

15.82

4.82

900

6.86

2.09

5000

18.01

5.49

1000

7.28

2.22

6000

20.06

6.12

1500

9.09

2.77

8000

23.82

7.26

1700

9.74

2.97

8800

25.24

7.7

Return Loss

806-960 MHz 

24.3dB

1700-2000 MHz 

24.3dB